What winter here does to a heat pump
Winter is the real question in Carbon County, because heat runs nine months a year here and cooling runs one. Whatever you pick is going to spend most of its life heating this house, so it needs to be good at that first.
The average overnight low from December through February is 15°F. A standard heat pump starts losing ground below 40°F, and below about 35°F it usually needs backup heat to keep up. Fifteen degrees is under both marks, and so is every one of the roughly 170 nights a year here that drop to freezing or below. That is more than half the nights in the nine months the heat is running.
This does not mean a heat pump quits. It means that on most winter nights here, a standard one is working below its rated output and leaning on backup heat to make up the difference. A cold-climate heat pump, the kind certified to hold at least 70 percent of its capacity at 5°F, is built for exactly this. Field tests of that kind of equipment found backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare above 0°F. The standard model and the cold-climate model are not the same purchase, and in this county that difference matters.
The nights that reach 0°F or below, about 8 a year, are a small slice of the winter. They are the stress test for backup heat, not the reason to rule a heat pump out.