What the cold does to a heat pump here
Winter here is long and it's cold enough to matter. Heat runs eight months a year, October through May, and the overnight low averages 20°F across December, January and February. That's not an occasional dip. About 160 nights a year, more than half the nights heat is running at all, drop to freezing or below.
A standard heat pump starts losing ground before it even gets near 20°F. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Your average winter night here is 20°F. Every single one of those 160 freezing nights is colder than both of those marks. This isn't a machine that dips below its comfort zone a few nights a year. It's a machine working below its comfort zone for most of the winter.
That doesn't mean it fails. Backup heat, usually electric resistance, is built in to cover exactly this. In a two winter field test of cold climate heat pumps in occupied homes, backup heat only carried a small share of the total load between 0°F and 35°F, and running on backup alone was rare except on the coldest nights. Millard County only sees about 6 nights a year at 0°F or below. So the backup is there for the real cold, not working constantly, but it is doing something on a lot of nights given how often this county sits below 35°F.
If you're set on a heat pump here, the fix is buying one rated for cold. A heat pump carrying the ENERGY STAR Cold Climate mark has to produce at least 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that same 5°F, checked by outside testing. A standard heat pump isn't built to that standard. In a county where half the winter nights are at or below freezing, that distinction is the one worth paying attention to.