What winter here does to a heat pump
Your winter low here averages 16°F, and that matters more than the running-cost numbers above. A standard heat pump starts losing capacity below 40°F and often needs backup heat below about 35°F. Sixteen degrees is under both marks, and so is every one of the roughly 195 nights a year that drop to freezing or below. That's over half the nights in the ten months your heat runs here.
So for most of your heating season, a standard heat pump isn't working at its rated output. It's running a backup heat source, usually electric resistance coils, to make up the difference. The $1.63 per 100,000 Btu figure above is the heat pump running at its rated efficiency with nothing added for that backup heat, so on most cold nights here your actual cost runs higher than that number.
A cold-climate heat pump changes this. To earn that label, a unit has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its 47°F capacity at that temperature, checked by outside testing. Field tests of these units in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and the units rarely ran on backup alone even above 0°F. Your ten nights a year near 0°F are the extreme case, not the typical one. Most of your cold nights sit well above it.