Most of Vernal heats with gas
Utility gas heats 60.2% of occupied homes in Uintah County. Electricity is next at 18.1%, with propane at 13.9%.
Takes about a minute. No obligation.
Utility gas heats 60.2% of occupied homes in Uintah County. Electricity is next at 18.1%, with propane at 13.9%.
Installing a heat pump in a home built around a gas furnace means adding a new way of heating, not swapping one part for another. Whoever quotes the job needs to look at what furnace and ductwork are already there before pricing it.

NOAA nClimDiv, 1991–2020 normals
The rating on a heat pump tells you how much heat it moves for the power it uses, not how big a house it can handle.
A unit sized wrong for the ductwork will run longer and wear faster no matter what the label says.




Uintah County sits in zone 6B, a cold, dry climate with winter running long. Any split-system heat pump installed here, if manufactured from 2023 on, has to clear federal minimums of 14.3 SEER2 for cooling and 7.5 HSPF2 for heating. Those numbers are a floor, not a recommendation, so a unit rated below them cannot legally go in no matter the price. A homeowner comparing quotes can ask to see the SEER2 and HSPF2 ratings printed on the equipment and check them against those minimums. There's also a federal tax credit available for qualifying heat pump installations, worth asking a contractor about when getting a quote.
Replace it before the season starts, so it happens on your schedule, not in a hurry.
Find a contractor
If the old system is a gas furnace, most of it comes out. The heat exchanger, burners and gas line get disconnected and removed, since a heat pump doesn't use any of that. What often stays is the ductwork and sometimes the air handler, if it's in good shape and sized right for the new equipment. An old condenser or AC unit outside gets hauled away and the new heat pump's outdoor unit takes its place on the pad. Any contractor doing the swap should also check the refrigerant lines, since older line sets aren't always rated for what a heat pump needs. Capping the gas line properly matters too, even if the furnace is long gone, so there's no line sitting live and unused.
Every heat pump loses some capacity as the temperature drops outside. What separates one system from another is how it makes up the difference. Some rely on a backup heat strip, others are built to keep pulling heat from the air well into the cold. Ask what kicks in when it's coldest and how the system decides to use it.
A contractor who sizes a heat pump should be able to point to a load calculation, not just a square footage chart. That calculation looks at the windows, the insulation, the ductwork already in place. Ask to see the number and what went into it, so the unit matches the house instead of a rule of thumb.
What drives the price of a heat pump installation has less to do with the unit itself and more to do with what has to change around it. Ductwork is a big piece of it. A heat pump moves a different volume of air than a gas furnace did, and ducts that were sized for the old system sometimes need modification to work with the new one. The electrical side matters too. A heat pump runs on electricity alone, so the breaker panel has to have the capacity to handle it, and some homes need an upgrade there before the unit ever gets installed. Where the outdoor unit sits and how far the line set has to run between indoor and outdoor components adds labor either way. And backup heat, if the system uses a heat strip for the coldest days, means more electrical work and sometimes a larger panel. None of this shows up on the equipment label. It shows up when someone actually looks at the house.
Install day starts with the old equipment coming out, and that takes longer than most people expect. Once the furnace and old condenser are gone, the crew sets the new outdoor unit on the pad and runs the line set to the indoor coil or air handler. Connections get brazed, then the whole line set gets pressure tested before any refrigerant goes in. A leak found after charging means starting over. The electrical hookup comes next, tying the unit into the breaker panel and running control wiring to the thermostat. Once it's wired and charged, the system gets run in cooling, then heating, then the defrost cycle if it has one. A contractor worth hiring checks airflow at every vent before calling it done.