Gas heats most homes here
Utility gas heats 66.4% of occupied homes in Iron County. Electricity is a distant second at 23.7%, with propane making up most of the rest.
Takes about a minute. No obligation.
Utility gas heats 66.4% of occupied homes in Iron County. Electricity is a distant second at 23.7%, with propane making up most of the rest.
Installing a heat pump in a gas-heated home means adding electric heating and cooling where a furnace used to do the heating alone. The ductwork question is one to check with a contractor before anything else is decided.

NOAA nClimDiv, 1991–2020 normals
Winter nights in Cedar City average 20°F, cold enough that a heat pump has real work to do for months at a time.
A heat pump sized for a 20°F night holds up without leaning on backup heat.



Heat here runs October through May, about eight months of the year. September is the month to get a heat pump installed, before the first cold night arrives. September installs also mean the system gets its first real test on a warm day, not a cold one, so a charge or airflow problem shows up before you need the heat to work. Wait until October and a contractor is fitting the job around your house already being cold, not around getting it right.
Iron County falls in climate zone 5B, where heating is the bigger job. New split-system heat pumps have to hit 14.3 SEER2 for cooling and 7.5 HSPF2 for heating at minimum. A federal tax credit is available toward the cost. A contractor can tell you which systems clear the minimum and qualify.
Find a contractor
If this is replacing a furnace, the furnace itself usually gets hauled off for scrap. There's no reuse market for an old gas furnace, and most are not worth the copper and steel in them once a contractor pulls the heat exchanger apart to confirm it's done. A furnace that's cracked a heat exchanger or lost its igniter for the third time is not a parts donor, it's scrap metal. If there's an old central air condenser sitting next to where the new heat pump will go, that comes out too. It gets disconnected, the line set gets drained of refrigerant the right way, and the unit goes with the rest of the old equipment. None of it gets left behind to make room for the new outdoor unit, since a heat pump needs its own clearance from walls and rooflines and an old condenser in the way defeats the purpose.
A contractor works out heat pump size by adding up how much heat each room loses through its walls, windows and roof, then checking how much heat the house needs replaced on the coldest nights. Square footage alone does not answer that. Houses the same size can need different size systems depending on insulation and window area.
A heat pump that is too big cycles on and off instead of running long steady stretches, so rooms end up uneven and the system wears faster from starting and stopping. One that is too small cannot keep up on the coldest days and leans hard on backup heat to make up the difference.
Ask what happens below freezing, not just how efficient the system runs on a mild day. Every heat pump loses capacity as the outdoor temperature drops, and the spec sheet should show output at a low temperature, not just at rated conditions. Ask what the backup heat is and when it switches on, because some systems lean on it earlier than others. Ask about the compressor, since a variable speed one holds steadier output in cold weather than a single stage unit cycling on and off. Ask who services the brand locally, because a system nobody nearby can get parts for turns a simple repair into a long wait. And ask for the sizing numbers in writing, room by room, not just a single tonnage figure written on a quote.
Install day starts with the old equipment coming out, not the new one going in. A contractor disconnects the furnace or old system, runs new line sets or confirms the existing ductwork will work with a heat pump, and sets the outdoor unit on a pad or bracket clear of walls and rooflines. Inside, the air handler or coil gets tied into the ductwork, and the electrical work gets done, since a heat pump draws differently than a gas furnace and may need a dedicated circuit or panel work. Once everything is connected, the system gets charged with refrigerant to the manufacturer's spec and run through its paces, heating and cooling both, so airflow and temperature split can be checked at the vents. A contractor should walk through the thermostat and backup heat settings before leaving, since a heat pump behaves differently than what a gas system trained you to expect.