What the cold actually does to a heat pump here
Winter here is the real question, since you heat your house nine months a year and cool it two. That nine to two split is why this decision is mostly about heating, whatever either machine does for air conditioning in July and August.
A standard heat pump starts losing its rated output below 40°F, and below about 35°F it usually needs backup heat to make up the difference. The average overnight low here in December, January and February is 18°F. That is under both marks, not close to the edge of them. And it is not just the average night. About 115 nights a year here drop to freezing or below, and every one of those nights is also under both marks.
That does not mean the heat pump quits. About one night a year here reaches 0°F, and even in cold-climate field testing, backup heat covered only a small share of the output between 0°F and 35°F, and running on backup alone was rare even at 0°F. A heat pump built and rated for cold climates, the ones carrying the ENERGY STAR Cold Climate mark, has to prove it still makes 1.75 units of heat per unit of electricity at 5°F and holds onto 70 percent of its 47°F capacity at that temperature. A standard heat pump, the kind priced at the federal minimum, was not built or tested to do that.