What the cold here does to a heat pump
Your winters set the terms of this choice. The overnight low here averages 12°F across December, January and February, and it falls to freezing or below on about 205 nights a year, out of the roughly 335 nights your heat runs at all. That's over half the heating season spent below freezing.
A standard heat pump puts out less than its rated heating capacity once it's below 40°F outside, and only a fraction of that rating once it reaches the teens. Below about 35°F it often needs backup heat to cover the rest. Your average winter night, 12°F, is below both of those marks, and so is every one of the 205 nights a year that drop to freezing or below. On most nights here, a standard heat pump is working under its rating and leaning on backup heat.
Real cold is the smaller piece of it. Only about 13 of those 205 nights reach 0°F or below. That's the number to ask about if you want a heat pump here. Look for the ENERGY STAR Cold Climate mark, which requires a heat pump to make at least 1.75 units of heat for every unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by independent testing. In field tests of these cold-climate units, backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump and a cold-climate one are not the same purchase here.