Your winters decide this, not the price per therm
Winter here runs long and gets cold. Heat runs eight months a year, October through May, and the overnight low averages 19°F across December, January and February. Six nights a year drop to 0°F or below. That's the climate a heat pump has to work in.
A standard heat pump starts losing ground before it gets anywhere near that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. Here, the average winter night is already past both marks. Of the roughly 245 nights heat runs, about 150 drop to freezing or below, more than half the season, and every one of those nights is below 40°F and below 35°F.
That doesn't mean a heat pump leaves you cold. It means a standard one is working outside its strong range for most of the winter, leaning on backup heat to hold the house at temperature. A gas furnace doesn't have that problem. It's built to put out full heat regardless of how cold it gets outside, which is exactly the shape of winter here.
There's a real exception. A heat pump built and certified for cold climates has to prove it still makes at least 1.75 units of heat per unit of electricity at 5°F, and holds onto 70 percent of its warm-weather capacity at that temperature, checked by independent testing. In a two-winter field test of prototype cold-climate heat pumps, backup heat covered only a small share of the load between 0°F and 35°F, and the homes rarely ran on backup alone even above 0°F. That's a different machine than the federal-minimum unit the running-cost numbers above are built on, and it's the one worth asking an installer about if you want a heat pump in this county.