Hail stays rare here
Kane County recorded 9 hail events between 2015 and 2024. That's the kind of damage that dents an outdoor unit or bends its fins, and it just doesn't happen often here.

Takes about a minute. No obligation.
Kane County recorded 9 hail events between 2015 and 2024. That's the kind of damage that dents an outdoor unit or bends its fins, and it just doesn't happen often here.
Winter nights average 23°F across December, January and February. A heat pump works harder below freezing, but that's a long way from the deep cold that wears a compressor down.

NOAA nClimDiv, 1991–2020 normals
Half the homes in Kane County were built in 1994 or later.
A heat pump that came with a newer house still has years of work left in it, so repair is usually the right call.




An aging heat pump usually tells on itself before it quits outright. It runs longer than it used to, or it blows air that's warm but not quite warm enough, or the outdoor unit ices up on mild days instead of just the cold ones. Any one of those is worth a service call, not a panic. The bigger question is what's failing. A bad capacitor, a low charge, a dirty coil, a failed contactor, these are all normal wear and tear, and fixing them brings the system back to where it should be. A compressor on its way out is a different matter, since that's the part that makes the whole system worth having, and replacing just that part rarely makes sense next to replacing the unit. Age matters here too, since a system nearing the end of its expected life that starts needing repairs every season is telling you something a single fix won't change.
It has an easier job here than in most places, so your heat pump is often in decent shape. Repair is usually worth it.
Find a contractorBefore anyone comes out, check the thermostat batteries and make sure it's set to heat, not auto, with the target a few degrees above room temperature. Go outside and look at the unit. If the fins are packed with leaves or the coil is caked in dirt, clear what you can reach by hand. Check that nothing is stacked against it or blocking airflow. Look at the outdoor coil for ice. A thin layer that clears during the defrost cycle is normal. A thick coat that doesn't go away points to a refrigerant or airflow problem underneath. Inside, pull the air filter and hold it up to a light. If you can't see light through it, replace it, since a clogged filter starves the system and can ice the coil from the inside out. Check the breaker box for anything tripped, both the indoor and outdoor disconnects. If the outdoor unit isn't running at all, listen for a hum. A hum with no fan movement usually means a part has failed and it's time to call someone rather than keep flipping the breaker.
Refrigerant doesn't get used up, so if the charge is low, it's leaking somewhere in the line set or coil. Keep running the system and it pulls in more moist air behind that leak, which can ice the coil and push the compressor to work harder than it's built for. The leak doesn't heal itself by running. It just gets more refrigerant out through the same hole.
Once ice builds past what the defrost cycle can clear, that ice blocks airflow across the coil. Less airflow means the coil gets even colder, which grows more ice. Left alone, that cycle can carry liquid refrigerant back into the compressor, which is the one part in the system that isn't worth repairing on its own.
Most heat pump problems announce themselves through sound or airflow before anything stops working. A grinding or squealing noise from the outdoor unit usually means a motor bearing is wearing out. Clicking that repeats without the system starting points to a failed capacitor or a relay that isn't closing. Weak airflow from the vents even when the thermostat calls for heat or cool often traces back to a failing blower motor or a duct that's come loose. Short cycling, where the system turns on and off every few minutes instead of running a full cycle, strains the compressor and is worth catching early. A system that runs constantly without reaching the set temperature is telling you it's lost capacity somewhere, whether that's a refrigerant leak or a coil that can't move heat the way it should.
A diagnostic visit starts outside at the unit itself. A tech checks the refrigerant pressures, the amp draw on the compressor and fan motors, and the condition of the coil and fins. Inside, they'll check the air handler or furnace coil, the blower, and the airflow through the ducts, since a system can be starved for air even when every part is working fine on its own. Electrical components get tested under load, not just looked at, because a capacitor or contactor can look fine sitting still and still fail the moment it has to do its job. The goal is to find the one thing that's actually wrong rather than guess from the symptom. Warm air that's not warm enough could point to a handful of different problems, and a tech narrows that down with gauges and a meter, not by swapping parts until something works.