August is when to catch it
Heat in Wasatch County homes typically starts up in September. If a heat pump has been sitting idle, August is the time to get it looked at, before it has to carry the load.

Takes about a minute. No obligation.
Heat in Wasatch County homes typically starts up in September. If a heat pump has been sitting idle, August is the time to get it looked at, before it has to carry the load.
Heat pumps here run about ten months a year, September through June. A part that was already marginal usually fails in the first cold weeks, not months into the run.

Winter storms have hit Wasatch County 104 times between 2015 and 2024.
A heat pump that struggles when the snow piles up usually has a problem it already had, not a new one.




If your heat pump came with the house, it's probably not old enough to be the reason it's acting up. A unit installed when the house was built in 2005 or later still has working life left in it. That changes the question a technician is answering. Instead of weighing repair against replacement, they're usually just finding the one part that failed, a capacitor, a contactor, a low charge, and fixing that. Worth knowing before you assume the whole system needs to go.
Problems tend to show up in the first weeks of the season, when the load hits a part that was already weak.
Find a contractor
A heat pump runs both directions, so it has more that can go wrong than a furnace that only ever heats. The reversing valve is the part unique to it, and a stuck valve usually shows up as the system blowing cold air when it should be heating. The defrost cycle is the other common failure point. It depends on a sensor and a control board talking to each other correctly, and when that fails, ice builds up on the outdoor coil and chokes off airflow until the unit can't pull heat from the air at all. The outdoor coil itself is exposed to wind and debris every day it sits out there, and a bent fin or a coil packed with dirt makes the system work harder for less heat. None of these are wear parts you can predict by age. They fail when they fail, and the cold snap just happens to be when you notice.
A heat pump low on refrigerant makes the compressor work harder to move the same amount of heat. Run it that way and the compressor runs hotter than it should, every cycle, until it burns out. What starts as a repair for a leak turns into a compressor replacement if it keeps running.
Once ice builds on the outdoor coil, airflow drops, and less airflow means the coil gets colder, which grows more ice. Left alone, it can block the fan entirely. A unit running iced over is also pulling in a lot more power to make a lot less heat.
Before you call, go outside and look at the unit. If the outdoor coil is caked in ice beyond the normal thin frost of a defrost cycle, flip the system off at the thermostat and let it thaw rather than running it iced over. Check that nothing is blocking the outdoor unit, no leaves, no snow drift, nothing sitting against the fins. Inside, check the thermostat is actually calling for heat and the batteries aren't dead, and check the air filter, since a clogged one starves the system of airflow and can mimic a bigger problem. Look at your breaker panel too. A tripped breaker can look like a dead system when the fix is that simple. If the outdoor fan isn't spinning at all, or you hear the compressor humming without the fan turning, stop there and get someone out. That's not something to keep running or try to force along.
A diagnostic visit starts outside at the unit itself, not with a clipboard. A technician checks refrigerant pressures, because that number tells them right away if the system is low on charge or moving heat the way it should. They'll check the amp draw on the compressor and the fan motor, since a motor pulling more current than it should is one that's working harder than it's built to. Inside, they're checking the temperature of the air coming off the vents against what the thermostat is calling for, which tells them if the heat pump is actually keeping up or just running without producing. They'll also run the defrost cycle on purpose, watching whether the control board and the sensor talk to each other the way they're supposed to. Most of this is them watching the system do what it does, then finding the one reading that's off.